Per and Dimitri,
I would like to come down stronger than that, for me it is a very strong requirement that the same switch can handle both VLANs and GMPLs trafic correctly. I can't dsee how that could be done if using the VLAN tpid to indicate GMPLS traffic.
/Loa
hi par, one of the possibilities that has been considered to cope with this requirement is to use a dedicated TPID for the Ethernet labeled frames; this would allow differentiated processing with non-labeled framesthanks.
That seems to make more sence. If that frame is to be sized like a 802.1q frame. There is not that much space left to a label. Or is the demand to use jumboframes ? Has there been any discussion on labelstacking, and mainly where to place the information?
Regards. Per
-- Loa Andersson
Principal Networking Architect Acreo AB phone: +46 8 632 77 14 Isafjordsgatan 22 mobile: +46 739 81 21 64 Kista, Sweden email: loa.andersson@acreo.se loa@pi.se