Hallo Dimitri,
You responded to Diego:
Diego Caviglia wrote:
Hi Dimitri,
given the high number of MS-SPRing protected transport
network
already deployed seems reasonable to me, from a Network Operator point of
view, to use at the same time MS-SPRing protection with GMPLS
restoration.
there are already two questions here 1. is there an operational need to
control such rings using GMPLS (? for instance is it effective knowing
that ring based protection is mainly data plane driven ?) and 2. how to
position the ring protection wrt to the LSP recovery segment/end-to-end
recovery
The first step in MS-Spring is indeed dataplane driven (using APS)
but that involves only nodes adjacent to the fault.
The reconfiguration of the ring after this first switch is controlplane
driven and concerns all nodes in the ring.
Cheers, Huub.
--
================================================================