[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Issue: Technical comments on draft-ietf-radext-ieee802-00.txt



Submitter name: David Nelson
Submitter email address: dnelson@enterasys.com
Date first submitted: August 10, 2005
Reference: (missing from the RADEXT archive ???)
Document: VLAN, Priority and Filtering Attributes
Comment type: 'T' Technical
Priority: '0' Must fix
Section: 3.1
Rationale/Explanation of issue:

Integer 
    
         The Integer field is four octets in length.  The format of the 
         Integer field consists of two parts, the first consuming high-
         order octet and the second consuming the remaining three lower-
         order octets.  The high-order octet field indicates if the 
         VLANID is allowed for tagged or untagged packets.  The second 
         part is the 12-bit 802.1Q VLAN VID value that has been padded 
         out to consume the remaining three lower-order octets.  A 
         sample encoding follows:  


This is not an Integer data type.  It is a multi-field Octet String
(complex data type).

Requested changes:

Express a String data type (with sub-fields).


--
to unsubscribe send a message to radiusext-request@ops.ietf.org with
the word 'unsubscribe' in a single line as the message text body.
archive: <http://psg.com/lists/radiusext/>