On Mon, Mar 20, 2006 at 02:06:16PM +0530, Nagi Reddy Jonnala (njonnala) wrote:
> Juergen, Bert and all,
> 
> We have two options then. Please let us know which one works for you.
> 
> 1. As Juergen suggested "This counter uses sysUpTime as the
> discontinuity indicator. Any discontinuity of this counter must cause a
> reset of 	sysUpTime."
> 
> 2. All we want to convey in the MIBs is that the counter might
> experience discontinuity when the respective (DAC or DAS) module is
> (re)started. Not sure if we need to draw any relation to sysUpTime or
> some other object. Is implementing the sysUptime mandatory? 

An SNMP agent without sysUptime (the default discontinuity indicator
for all counters) is kind of broken.

> If not, does the below work?
> 
> "This counter may experience discontinuity when the Dynamic
> Authorization Client (DAC) module is (re)started".

Why only the DAC module?

/js

-- 
Juergen Schoenwaelder		    International University Bremen