Re: cr computation



Hi, Balazs

Actually, our draft (draft-iwata-mpls-crankback-00.txt) was improved 
version of draft "draft-fujita-mpls-crldp-crankback-00.txt", which was 
issued on Mar.2000, and "draft-fujita-mpls-crldp-crankback-01.txt" on 
Jul.2000. The basic difference of these drafts are crankback routing 
behaviors of RSVP-TE signaling.

The current status of this draft is still an individual document on CCAMP 
WG, as Kireeti suggested. In order to make this draft WG draft, it requires 
recommendations and requirements from the design team for hierarchical TE. 

Kireeti, could you please let us know the status of this design team.

Thank you.

At 16:46 01/06/18 +0200, Balazs Szviatovszki wrote:
>What is the status of the mentioned draft?
>
>draft-iwata-mpls-crankback-00.txt
>
>Balazs
>
----------------------------------------------------------------
Atsushi Iwata, Ph.D.
Principal Researcher
Network Architecture TG, Networking Research Labs, NEC Corporation
4-1-1 Miyazaki Miyamae-ku, Kawasaki, 216-8555, Japan
TEL: +81-44-856-2123 (Direct), Fax: +81-44-856-2230 (Direct)
NEC-internal TEL: 8-272-3281, NEC-internal FAX: 8-272-3299
Internet E-mail:     a-iwata@ah.jp.nec.com
NEC-internal E-mail: iwata@ccm.CL.nec.co.jp

*** Organization has been a bit changed since Apr.2001 ***