Manoj,
In pure SDH, you can not allocate STM-64 within STM-256. You can allocate
VC-4-64c link connection within a HOVC link. The associated timeslot is an
AU-4-64c, which is identified in EDCBA terminology with 10000, 20000, 30000, or
40000. If you look in my g707-gmpls-label-conversion document, you see that
10000 maps on S U = 1 0
20000 maps on S U = 65 0
30000 maps on S U = 129 0
40000 maps on S U = 193 0
KLM in all cases is 000 (i.e. non relevant).
As it is a contiguous concatenated signal, there is just 1 label, identifying
the first timeslot. Assume you want to pass the VC-4-64c via AU-4-64c 20000,
then the label looks like:
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| ST=6 | RCC=1 | NCC=64 |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| NVC=0 | Multiplier (MT)=1 |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Transparency (T)=0 |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| S=65 | U=0 | K=0 | L=0 | M=0 |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
Regards,
Maarten
manoj juneja wrote:
>
> Hi All,
> If I want to allocate STM-M from STM-N (M < N) then what will be the
> label value in GMPLS ? I mean to say if I get a request to allocate STM-64
> from STM-256 link then what will be the label value (SUKLM) and how many
> labels will be sent back in RESV message ?
>
> Please comment.
>
> Regards,
> manoj
>
> _________________________________________________________________
> Get your FREE download of MSN Explorer at http://explorer.msn.com/intl.asp
begin:vcard
n:Vissers;Maarten
tel;cell:+31 62 061 3945
tel;fax:+31 35 687 5976
tel;home:+31 35 526 5463
tel;work:+31 35 687 4270
x-mozilla-html:FALSE
org:Optical Network Group;Lucent Technologies Nederland
version:2.1
email;internet:mvissers@lucent.com
title:Consulting Member of Technical Staff
adr;quoted-printable:;;Botterstraat 45=0D=0A=0D=0A;1271 XL Huizen;;;The Netherlands
fn:Maarten Vissers
end:vcard